        IEC 60598-1: 2020 edition standard update instructions

        Author:中認(rèn)聯(lián)科 time:2020-09-21 Ctr:3686

        IEC 60598-1:2020 luminaires. Part 1 of general requirements and tests was officially released on August 17, 2020. IEC 60598-1:2020 is the ninth edition released this time and will replace IEC 60598-1:2014+A1 : The 2017 version.

        image.png

        Compared with the previous version, the new version includes the following major technical changes:

        1. Add PELV and related requirements. Due to transient protection circuits and EMC reasons, the market has a strong demand for PELV circuits. Considering IEC TR 63139 (under development), where SELV appears in the standard, the addition of PELV related modifications involves Chapter 3, Chapter 4, Chapter 7, Chapter 8, Chapter 10, Appendix X, etc.;

        2. Modified Table 10.3 and Article 3.3.19 for high protection currents. According to the regulations stated in the manual of 3.3.19, the power supply current limit of 20A or more shall be added on the basis of the original applicable objects, that is, the applicable objects of this clause are Permanently connected lamps with a power supply current of more than 20A and a protective conductor current of more than 10 mA, and the corresponding limit in Table 10.3 is changed from 10 mA to 10 mA or in accordance with the manufacturer’s instructions;

        3. Article 3.3.26 adds the marking requirements for wall-mounted lamps within the reach of the arm, and requires additional instructions for fixing the cable to the wall;

        4. Article 3.2.27 adds requirements for constant light output function and programmable current output;

        5. Article 4.30 Non-user replaces the electric shock protection cover used for light source lamps;

        6. Article 4.24.2 Blu-ray hazards delete category 0 hazards;

        7. Article 5.2.16 adds the component standard IEC 61984 that the connector should comply with, as well as additional requirements such as polarity interchange, mechanical locking, protection against electric shock, short circuit protection, and cable clamping;

        8. Article 3.3.25 adds the requirements of cable UV protection;

        9. Article 4.34 requires lamps not to emit harmful electromagnetic fields and should comply with EMF IEC 62493;

        10. Updated the functional grounding and protective grounding and their requirements in the 1.2.73 standard, including adding definitions, adding the qualifiers of "function" or "protection" to "grounding" in the clauses; in Appendix G, adding The description of the disconnection of the functional ground (if separate) when measuring the protective conductor current is added, and the functional ground terminal or contact that can be touched should be regarded as an accessible part and tested when measuring the contact current;

        11. Article 4.35 puts forward the test requirements to prevent the fan blades driven by the motor for cooling in the lamps from being touched, and gives the exemption test conditions, such as low hardness, low speed and low power;

        12. Article 3.2.2 Modify the marking requirements of rated voltage, delete the situation that does not need to be marked with rated voltage, that is, all lamps must be marked with rated voltage in volts;

        13. In the provisions of Article 5.2.10, the provisions that meet the requirements of 5.2.10.4 can be used as an exception to the use of flexible cord holders. The additional 5.2.10.4 provides for exceptional conditions, including overcurrent protection devices. The highest short-circuit current reached does not exceed 2A, and the highest voltage of various Class III lamps, and the corresponding qualification test requirements;

        14. The measurement network in Appendix G for the measurement of contact current and protective conductor current is revised;

        15. Modified the contact voltage limit value of irregular DC voltage in 8.2.3c);

        16. Article 1.2.96 Luminaires (PoE) that rely on Ethernet power supply that meets IEC 62368-3 power supply are connected, involving definitions, structures, thermal tests and an appendix introducing PoE luminaires;

        17. Article 9 IP adds high pressure and high temperature water blowout protection IPX9 (80℃) and high pressure and low temperature water blowout protection IPX9 (15℃) and its test requirements;

        18. Amended Appendix D to introduce alternative thermal tests for lamps whose ta mark is higher than 25℃;

        19. In Article 0.2, 4.14.1 was added, and relevant requirements for rail-mounted luminaires were added, including definitions, and rail-mounted luminaires were added to 4.14.1 test objects, and a requirement was added in Chapter 4, that is, rail-mounted luminaires It shall be tested in accordance with IEC 60570 Annex A;

        20. The test method of 10.2.2 to increase the electrical strength of DC lamps is modified;

        21. Amended Appendix D and added the temperature limit to Table 12.1 and Table 12.3. For lamps marked with F, the covering layer is changed to directly contact the lamp instead of covering the outside of the box before;

        22. The minimum torque of the metal gland test in Table 4.2 is reduced from 6.25 Nm to 4 Nm;

        23. Amend the requirements for protective impedance devices (4.10.4) in Section 4.10.4 and Appendix U, and modify the quantity requirements of Y1 and Y2 to be expressed in tables, and according to the power supply voltage, impulse withstand category, and insulation of the jumper And the number of capacitors required by the capacitor type (Y1, Y2 or Y4). The relevant amendments involve Chapter 4 and Appendix U;

        24. Amend the second paragraph of 5.2.14 to modify the category III plugs used in lamps and lanterns, in the original requirement that category III plugs cannot be connected to the grid power socket, "cannot be connected" is changed to "cannot be electrically connected", and The test method is added, and the relevant modification involves Chapter 5 and Chapter 4.


        Related Articles
        • 3D printers to be exported to South Korea? Please keep the KC certification and customs clearance guide handy

        • Wireless label printers comply with international standards and go global: Key points of ISED IC certification

        • Successfully obtain ISED IC certification, and the Bluetooth headphones can easily enter the Canadian market.

        • CCC Certification for Lithium Iron Phosphate Batteries for Electric Bicycles: Regulatory Requirements and Compliance Key Points

        Follow Us
        主站蜘蛛池模板: 国产精品成人三级| 欧美乱大交xxxxx疯狂俱乐部| 免费观看羞羞视频网站| 亚洲在线中文字幕| 国产一区二区三区免费主播| 国产精品乱码久久久久久小说| 国产精品18久久久| 老司机午夜精品99久久免费| 西吉县| 丰满人妻被黑人猛烈进入| 日韩午夜福利| 日韩精品一二三四五区| 激情综合网激情综合| 激情综合五月网| 在线精品无码字幕无码av| 国产成人久久精品一区二区| 中文字幕乱码在线播放| 成人自拍网| 狠狠色丁香婷婷综合| 3p小视频| 国产精品人| 91sese| av熟女一区二区久久| 国产99久久亚洲综合精品西瓜tv| 377人体粉嫩噜噜噜| 国模粉嫩小泬视频在线观看| 午夜福利精品在线观看| 欧美mv日韩mv国产网站app | A级毛片18以上观看视频免费| 亚洲综合第一色| 国产成人做爰A片免费胖人| 免费无码又爽又刺激高潮的视频网站| 亚洲一区二区三区在线播放无码| 瑜伽裤国产一区二区三区| 九九热在线视频| 亚洲中文字幕久久精品蜜桃| 成人免费一区二区三区视频| 91色综合综合热五月激情| 欧美人与动人物牲交免费观看久久 | 日韩有码av中文字幕| 非会员区试看120秒6次|